Description
EDISON SB FO E PS CI HI WPA HRO SR
HRD060D
CE EN ISO 20345:2022 SB FO E PS CI HI WPA HRO SR
High safety shoe, WPA back leather and heel in anti-scratch leather thickness 1,8-2,0 mm, with refracting fabric insert.
Perspiring and abrasion resistant fabric lining.
Soft, lined and padded tongue.
COMPLETELY METAL FREE SHOE
TOECAP 200J polymeric composite non-thermic according to EN 22568
PS MIDSOLE fabric INSULATION composite flexible anti-perforation according to EN 22568
SOLE HARD ROCK INSULATING bidensity polyurethane and INSULATING RUBBER resistant to hydrocarbons and to abrasion, anti-shock and anti-slipping
– The bottom of the shoe, within some limits (no humidity, it doesn’t concern the upper), offers electrical resistance against tension up to 1.000V – M 0hm > 1.000
– Electrical resistance: CSA Z195-14 Canadian standard increase 1 kV/sec – voltage 20.000V /60 hz – duration 1 minute. Electric flow requirement less than 1,0 mA
– Electrical resistance: ASTM F2413 -24 (similar to ASTM F2412:2024) – 1 kV/sec increment voltage 20000 V/60 Hz – duration 1 minute. Electrical flow requirement less than 1.0 mA.
DIELECTRIC INSOLE bimaterial extracomfort with activated carbon, breathable, removable, anatomical, absorbent, insulating and antibacterial.
Environmentally Sustainable Eco-Friendly
FO sole resistance to hydrocarbons
E energy absorption on seat region
PS sole resistance to perforation non metallic (nail Ø3,0mm)
CI cold insulation of sole complex -17°C
HI heat insulation of sole complex
HRO resistance to hot contact of the outsole
SR sole resistance against slipping
Perspiring and abrasion resistant fabric lining.
Soft, lined and padded tongue.
COMPLETELY METAL FREE SHOE
TOECAP 200J polymeric composite non-thermic according to EN 22568
PS MIDSOLE fabric INSULATION composite flexible anti-perforation according to EN 22568
SOLE HARD ROCK INSULATING bidensity polyurethane and INSULATING RUBBER resistant to hydrocarbons and to abrasion, anti-shock and anti-slipping
– The bottom of the shoe, within some limits (no humidity, it doesn’t concern the upper), offers electrical resistance against tension up to 1.000V – M 0hm > 1.000
– Electrical resistance: CSA Z195-14 Canadian standard increase 1 kV/sec – voltage 20.000V /60 hz – duration 1 minute. Electric flow requirement less than 1,0 mA
– Electrical resistance: ASTM F2413 -24 (similar to ASTM F2412:2024) – 1 kV/sec increment voltage 20000 V/60 Hz – duration 1 minute. Electrical flow requirement less than 1.0 mA.
DIELECTRIC INSOLE bimaterial extracomfort with activated carbon, breathable, removable, anatomical, absorbent, insulating and antibacterial.
Environmentally Sustainable Eco-Friendly
FO sole resistance to hydrocarbons
E energy absorption on seat region
PS sole resistance to perforation non metallic (nail Ø3,0mm)
CI cold insulation of sole complex -17°C
HI heat insulation of sole complex
HRO resistance to hot contact of the outsole
SR sole resistance against slipping
THIS PRODUCT COMPLIES WITH THE REQUIREMENTS OF THE STANDARD ASTM F2413-24:
– Impact resistant footwear (I)
– Compression resistant footwear (C)
– Puncture Resistant Footwear (PR)
– Electric Hazard Resistant Footwear (EH)
– Slip Resistance (SRO)
Size 37-48 Shoe weight Sz 42 gr. 625* The weight is calculated without laces and insole.
*Availability is constantly changing, contact us to receive the latest update.